2,317 research outputs found

    Pulmonary embolism in patients with COVID-19 and value of D-dimer assessment:a meta-analysis

    Get PDF
    Purpose To investigate, in a meta-analysis, the frequency of pulmonary embolism (PE) in patients with COVID-19 and whether D-dimer assessment may be useful to select patients for computed tomography pulmonary angiography (CTPA). Methods A systematic literature search was performed for original studies which reported the frequency of PE on CTPA in patients with COVID-19. The frequency of PE, the location of PE, and the standardized mean difference (SMD) of D-dimer levels between patients with and without PE were pooled by random effects models. Results Seventy-one studies were included. Pooled frequencies of PE in patients with COVID-19 at the emergency department (ED), general wards, and intensive care unit (ICU) were 17.9% (95% CI: 12.0-23.8%), 23.9% (95% CI: 15.2-32.7%), and 48.6% (95% CI: 41.0-56.1%), respectively. PE was more commonly located in peripheral than in main pulmonary arteries (pooled frequency of 65.3% [95% CI: 60.0-70.1%] vs. 32.9% [95% CI: 26.7-39.0%]; OR = 3.540 [95% CI: 2.308-5.431%]). Patients with PE had significantly higher D-dimer levels (pooled SMD of 1.096 [95% CI, 0.844-1.349]). D-dimer cutoff levels which have been used to identify patients with PE varied between 1000 and 4800 mu g/L. Conclusion The frequency of PE in patients with COVID-19 is highest in the ICU, followed by general wards and the ED. PE in COVID-19 is more commonly located in peripheral than in central pulmonary arteries, which suggests local thrombosis to play a major role. D-dimer assessment may help to select patients with COVID-19 for CTPA, using D-dimer cutoff levels of at least 1000 mu g/L

    Peer review practices by medical imaging journals

    Get PDF
    ObjectiveTo investigate peer review practices by medical imaging journals.MethodsJournals in the category "radiology, nuclear medicine and medical imaging" of the 2018 Journal Citation Reports were included.ResultsOf 119 included journals, 62 (52.1%) used single-blinded peer review, 49 (41.2%) used double-blinded peer review, two (1.7%) used open peer review and one (0.8%) used both single-blinded and double-blinded peer reviews, while the peer review model of five journals (4.2%) remained unclear. The use of single-blinded peer review was significantly associated with a journal's impact factor (correlation coefficient of 0.218, P=0.022). On subgroup analysis, only subspecialty medical imaging journals had a significant association between the use of single-blinded peer review and a journal's impact factor (correlation coefficient of 0.354, P=0.025). Forty-eight journals (40.3%) had a reviewer preference option, 48 journals (40.3%) did not have a reviewer recommendation option, and 23 journals (19.3%) obliged authors to indicate reviewers on their manuscript submission systems. Sixty-four journals (53.8%) did not provide an explicit option on their manuscript submission Web site to indicate nonpreferred reviewers, whereas 55 (46.2%) did. There were no significant associations between the option or obligation to indicate preferred or nonpreferred reviewers and a journal's impact factor.ConclusionSingle-blinded peer review and the option or obligation to indicate preferred or nonpreferred reviewers are frequently employed by medical imaging journals. Single-blinded review is (weakly) associated with a higher impact factor, also for subspecialty journals. The option or obligation to indicate preferred or nonpreferred reviewers is evenly distributed among journals, regardless of impact factor

    Systematic Review and Meta-Analysis on the Value of Chest CT in the Diagnosis of Coronavirus Disease (COVID-19):Sol Scientiae, Illustra Nos

    Get PDF
    OBJECTIVE. The purpose of this article is to systematically review and meta-analyze the diagnostic accuracy of chest CT in detecting coronavirus disease (COVID-19). MATERIALS AND METHODS. MEDLINE was systematically searched for publications on the diagnostic performance of chest CT in detecting COVID-19. Methodologic quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Meta-analysis was performed using a bivariate random-effects model. RESULTS. Six studies were included, comprising 1431 patients. All six studies included patients at high risk of COVID-19, and five studies explicitly reported that they included only symptomatic patients. Mean prevalence of COVID-19 was 47.9% (range, 27.6–85.4%). High or potential risk of bias was present throughout all QUADAS-2 domains in all six studies. Sensitivity ranged from 92.9% to 97.0%, and specificity ranged from 25.0% to 71.9%, with pooled estimates of 94.6% (95% CI, 91.9–96.4%) and 46.0% (95% CI, 31.9–60.7%), respectively. The included studies were statistically homogeneous in their estimates of sensitivity (p = 0.578) and statistically heterogeneous in their estimates of specificity (p < 0.001). CONCLUSION. Diagnostic accuracy studies on chest CT in COVID-19 suffer from methodologic quality issues. Chest CT appears to have a relatively high sensitivity in symptomatic patients at high risk of COVID-19, but it cannot exclude COVID-19. Specificity is poor. These data, along with other local factors such as COVID-19 prevalence, available real-time reverse transcriptase–polymerase chain reaction tests, staff, hospital, and CT scanning capacity, can be useful to healthcare professionals and policy makers to decide on the utility of chest CT for COVID-19 detection in the hospital setting

    Systematic review on the value of end-of-treatment FDG-PET in improving overall survival of lymphoma patients

    Get PDF
    This study aimed to systematically review the value of end-of-treatment 18F-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) in improving overall survival (OS) of lymphoma patients. Medline was systematically searched for (1) randomized trials comparing the OS of patients who underwent end-of-treatment FDG-PET to those without and FDG-PET-based end-of-treatment evaluation and for (2) non-randomized studies comparing the OS of patients who underwent end-of-treatment FDG-PET to a (historical) cohort of patients without an FDG-PET-based end-of-treatment evaluation. The Medline search revealed 6284 articles. However, none of these reported data on the value of end-of-treatment FDG-PET in improving OS of lymphoma patients. In conclusion, the present systematic review reveals that there is currently no study at all that evaluates the value of end-of-treatment FDG-PET in improving OS of lymphoma patients. As a result, it remains unknown whether end-of-treatment FDG-PET increases OS and in which lymphoma subtype these examinations are of particular value. Future studies are required to demonstrate its value in this setting before it can be recommended as an evidence-based diagnostic tool by guidelines on the use of imaging in lymphoma

    Chest CT Imaging Signature of Coronavirus Disease 2019 Infection In Pursuit of the Scientific Evidence:in pursuit of the scientific evidence

    Get PDF
    BACKGROUND: Chest CT may be used for the diagnosis of coronavirus disease 2019 (COVID-19), but clear scientific evidence is lacking. Therefore, we systematically reviewed and meta-analyzed the chest CT imaging signature of COVID-19.RESEARCH QUESTION: What is the chest CT imaging signature of COVID-19 infection?STUDY DESIGN AND METHODS: A systematic literature search was performed for original studies on chest CT imaging findings in patients with COVID-19. Methodologic quality of studies was evaluated. Pooled prevalence of chest CT imaging findings were calculated with the use of a random effects model in case of between-study heterogeneity (predefined as I-2 =50); otherwise, a fixed effects model was used.RESULTS: Twenty-eight studies were included. The median number of patients with COVID-19 per study was 124 (range, 50-476), comprising a total of 3,466 patients. Median prevalence of symptomatic patients was 99% (range, &gt;76.3%-100%). Twenty-seven of the studies (96%) had a retrospective design. Methodologic quality concerns were present with either risk of or actual referral bias (13 studies), patient spectrum bias (eight studies), disease progression bias (26 studies), observer variability bias (27 studies), and test review bias (14 studies). Pooled prevalence was 10.6% for normal chest CT imaging findings. Pooled prevalences were 90.0% for posterior predilection, 81.0% for ground-glass opacity, 75.8% for bilateral abnormalities, 73.1% for left lower lobe involvement, 72.9% for vascular thickening, and 72.2% for right lower lobe involvement. Pooled prevalences were 5.2% for pleural effusion, 5.1% for lymphadenopathy, 4.1% for airway secretions/tree-in-bud sign, 3.6% for central lesion distribution, 2.7% for pericardial effusion, and 0.7% for cavitation/cystic changes. Pooled prevalences of other CT imaging findings ranged between 10.5% and 63.2%.INTERPRETATION: Studies on chest CT imaging findings in COVID-19 suffer from methodologic quality concerns. More high-quality research is necessary to establish diagnostic CT criteria for COVID-19. Based on the available evidence that requires cautious interpretation, several chest CT imaging findings appear to be suggestive of COVID-19, but normal chest CT imaging findings do not exclude COVID-19, not even in symptomatic patients.</p
    • …
    corecore